Interlock FR fabric sets a new standard in comfort and safety! With Tru-Spec X-Fire, police departments and tactical squads can outfit more of their officers with affordable fire-resistant protection than ever before.

  • TRU-SPEC Industrial Flash Fire Protective Garments are UL-certified for compliance with NFPA 2112, Standard on Flame-Resistant Garments for Protection of Industrial Personnel Against Flash Fire, 2007 Edition
  • 10-pocket design:
  • 2 easy access slanted cargo pockets with drain holes, 5"x5" hidden pocket and elastic drawstring with cord lock for secure closure
  • 2 extra-deep front slash pockets with reinforced openings
  • 2 bellowed lower leg pockets with hook-and-loop closures
  • Hook-and-loop closure pocket flaps
  • 1"-wide belt loops with 2-1/4" openings
  • Drawstring waist with button fly
  • Reinforced seat
  • Reinforced internal knee pockets for knee pad inserts with easy access external hook-and-loop openings
  • "Stay Tied" heavy drawstring leg ties
  • Tested by the best. TRU-SPEC Industrial Flash Fire Protective Garments are UL-certified for compliance with NFPA 2112, Standard on Flame-Resistant Garments for Protection of Industrial Personnel Against Flash Fire, 2007 Edition
  • X-Fire by Tru-Spec Interlock fabric sets a new standard in comfort and safety for all public safety and military apparel:
  • Safety and Comfort: 6.5 oz. Interlock fabric combines the safety of fire-resistant (FR) fabrics with the comfort and moisture wicking ability of a cotton blend
  • Durability: The 80% FR-treated cotton of the X-Fire Interlock fabric is a naturally durable fabric that does not need to be mixed with other fibers to increase the durability of the material and loses none of its inherent thermal protection in the process
  • Increased Comfort: The 80% cotton gives the feel and comfort of an all-cotton garment because the cotton is blended with the warp and filling yarns allowing for a cotton feel both inside and out
  • Equal or Similar Flame-Resistant Properties: Interlock cotton fabrics are treated with a durable FR chemical treatment that lock the flame-resistant properties in the fabric. Fabrics treated with this process were tested after 100 washings and showed no loss in FR properties with a char length of 2.0" to 2.5"
  • X-Fire by Tru-Spec Interlock fabric meets or exceeds the following testing standards (results confirmed and provided by Mount Vernon Mills):
  • NFPA 2112
  • A.S.T.M. 1930 Manikin burn test (performed at DuPont, witnessed by UL)
  • ASTM D6413 Char length and confirmation of No Melt No Drip fabric
  • ASTM 1506-08 Standard performance specification for wearing apparel for use by electrical workers to momentary arc and related thermal hazards
  • ASTM F 1959 Test determines arc rating
  • ASTM D 6413 Char length and No Melt No Drip verification
  • NFPA 70 E Standard for electrical safety in the workplace In Compliance
  • X-Fire by Tru-Spec Interlock fabric meets or exceeds the following testing standards (results confirmed and provided by UL):
  • NFPA 2112-2007: Under Writers Lab Certified
  • ASTM 1930 Manikin Test Results: 37% Body Burn (Maximum Requirement 50%)
  • ASTM D 6413 Test Method for Vertical Flame Resistance of Textiles. Results: Char length Original 67.2 x 64.0 mm (Maximum allowed 100 mm)
  • Char length 100 ILs 51.2 x 57.6mm (Maximum allowed 100mm). Flammability No Melting No Dripping After Flame 0 Sec (Maximum Requirement 2 Sec)
  • T.P.P. Test Results: Contact 8.4 cal/cm2 @ Original (Min Requirement 3.0 Contact)
  • TPP Test Results: Contact 9.0 cal/cm2 @ 25 Washes (Min Requirement 3.0 Contact)
  • TPP Test Results: Spaced 8.5 cal/cm2 @ Original (Min Requirement 6.0 Spaced)
  • TPP Test Results: Spaced 9.2 cal/cm2 @ 25 Washes (Min Requirement 6.0 Spaced)
  • Heat and Thermal Shrinkage Resistance Test Results: 1.9 x .6 % Original (Max Requirement 10%); 1.3 x .7 % After Wash (Max Requirement 10%)
  • ASTM 1506-08 Standard Performance Specification for Wearing Apparel for use by Electrical Workers to Momentary Electric Arc and Related Thermal Hazards In Compliance
  • ASTM F 1959 Standard Test Method for Determining Arc Rating of Materials for Clothing Arc Rating 6.1 cal/cm2 In Compliance
  • ASTM D 6413 Results: As above (Maximum allowed 6") In Compliance
  • NFPA 70 E Standard for Electrical Safety in the Workplace In Compliance, Meets ASTM 1506 and ASTM F 1959
  • Other Tests: Air Perm 9.5 cfm
  • NFPA 1977 Standard on Protective Clothing & Equipment for Wildland Fire Fighting, RPP 8.79 (Min 7.00) Tested by Dupont; THL Being Tested by Under Writers Lab

Height: Short: 5'3" - 5'5" | Regular: 5'6" - 5'9" | Long: 5'10" - 6'3"